The EPC 1100
includes: 3 inputs for 1 or more
of the following:
- 1 or more room
temperature sensors
- Humidity sensor
- Alarm temperature
sensor
- Heatlamp or
heatpad sensor
- Outside
temperature sensor
Outside temperature sensor 2 variable
outputs ( 8 ) amp each for 1 or more of the following:
- 1 or 2 variable
fan stages
- Variable headlamp
or heatpad
- Variable heat
Variable heat 2 0 –10 VDC outputs for
1 or more of the following:
- 1 or 2 variable
fan stages
- Variable heatlamp
or heatpad
- Variable heat
- Second stage
inlet control
4 relay outputs ( 10 ) amp each for 1
or more of the following:
- 1 to 4 fixed fan
stages
- Heater control (
up to 2 stages )
- Fogger timer
- Alarm output
- Time clocks ( up
to 4 separate )
- On/off heatlamp
control
1 solid state 24 VDC inlet control
- Actuator control
using potentiometer feedback
- Or actuator
control using static pressure sensor
1 communication port for interfacing
with:
- Host computer
- Future alarm
system
|
The EPC 1500 control includes:
3 inputs for 1
or more of the following:
- 1 or more room temperature sensors
- Humidity sensor
- Alarm temperature sensor
- Floor heat sensor
- Outside temperature sensor
2 variable outputs ( 8 ) amp each for 1 or more of the following:
- 1 or 2 variable fan stages
- Variable heat
Variable heat 2 0 –10 VDC outputs for 1 or more of the following:
- 1 or 2 variable fan stages
- Variable floor heat
- Variable heat
- Second stage inlet control
8 relay outputs ( 10 ) amp each for 1 or more of the following:
- 1 to 8 fixed fan stages
- Heater control ( up to 2 stages )
- Fogger timer
- Alarm output
- Time clocks ( up to 4 separate )
- Curtain control
1 solid state 24 VDC inlet control
- Actuator control using potentiometer feedback
- Or actuator control using static pressure sensor
1 communication port for interfacing with:
- Host computer
- Future alarm system
|
The EPC 1700 control includes:
3 inputs for 1
or more of the following:
- 1 or more room temperature sensors
- Humidity sensor
- Alarm temperature sensor
- Floor heat sensor
- Outside temperature sensor
2 variable outputs ( 8 ) amp each for 1 or more of the following:
- 1 or 2 variable fan stages
- Variable heat
(2) 0 –10 VDC outputs for 1 or more of the following:
- 1 or 2 variable fan stages
- Variable heat
- Second stage inlet control
16 relay outputs ( 10 ) amp each for 1 or more of the
following:
- 1 to 6 fixed fan stages
- Heater control ( up to 2 stages )
- Fogger timer
- Alarm output
- Time clocks ( up to 4 separate )
- Curtain control including potentiometer feedback for
ridge and two curtains
- Actuator control using potentiometer feedback
1 solid state 24 VDC inlet control
- Actuator control using potentiometer feedback
- Or actuator control using static pressure sensor
1 communication port for interfacing with:
- Host computer
- Future alarm system
|